XRT72L50 Datasheet, PDF (218/471 Pages) Exar Corporation – SINGLE CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER
XRT72L50
SINGLE CHANNEL DS3/E3 FRAMER WITH HDLC CONTROLLER
REV. 1.2.1
áç
The Receive DS3 HDLC Controller block can be used to receive either bit-oriented signaling (BOS) or
message-oriented signaling (MOS) type data link messages. The Receive DS3 HDLC Controller block can
also be configured to receive both types of message from the remote terminal equipment.
Both BOS and MOS types of HDLC message processing are discussed in detail below.
4.3.3.1 Bit-Oriented Signaling (or FEAC) Processing via the Receive DS3 HDLC Controller.
The Receive DS3 HDLC Controller block consists of two major sub-blocks
• The Receive FEAC Processor
• The LAPD Receiver
This section describes how to operate the Receive FEAC Processor.
If the Receive DS3 Framer block is operating in the C-bit Parity Framing format, then the FEAC bit-field within
the DS3 Frame can be used to receive FEAC (Far End Alarm and Control) messages (See Figure 72). Each
FEAC code word is actually six bits in length. However, this six bit FEAC Code word is encapsulated with 10
framing bits to form a 16 bit message of the form:
FEAC CODE WORD
FRAMING
0 d5 d4 d3 d2 d1 d0 0
1
1
1
1
1
1
1
1
Where, [d5, d4, d3, d2, d1, d0] is the FEAC Code word. The rightmost bit of the 16-bit data structure (e.g., a 1)
will be received first. Since each DS3 Frame contains only 1 FEAC bit-field, 16 DS3 Frames are required to
transmit the 16 bit FEAC code message. The six bits, labeled d5 through d0 can represent 64 distinct
messages, of which 43 have been defined in the standards.
The Receive FEAC Processor frames and validates the incoming FEAC data from the remote Transmit FEAC
Processor via the received FEAC channel. Additionally, the Receive FEAC Processor will write the Received
FEAC code words into an 8 bit Rx-FEAC register. Framing is performed by looking for two 0s spaced 6 bits
apart preceded by 8 1s. The Receive DS3 HDLC Controller contains two registers that support FEAC Message
Reception.
• Rx DS3 FEAC Register (Address = 0x16)
• Rx DS3 FEAC Interrupt Enable/Status Register (Address = 0x17)
The Receive FEAC Processor generates an interrupt upon validation and removal of the incoming FEAC Code
words.
Operation of the Receive DS3 FEAC Processor
The Receive FEAC Processor will validate or remove FEAC code words that it receives from the remote
Transmit FEAC Processor. The FEAC Code Validation and Removal functions are described below.
FEAC Code Validation
When the remote terminal equipment wishes to send a FEAC message to the Local Receive FEAC Processor,
it (the remote terminal equipment) will transmit this 16 bit message, repeatedly for a total of 10 times. The
Receive FEAC Processor will frame to this incoming FEAC Code Message, and will attempt to validate this
message. Once the Receive FEAC Processor has received the same FEAC code word in at least 8 out of the
last 10 received codes, it will validate this code word by writing this 6 bit code word into the Receive DS3 FEAC
Register. The Receive FEAC Processor will then inform the µC/µP of this Receive FEAC validation event by
generating a Rx FEAC Valid interrupt and asserting the FEAC Valid and the RxFEAC Valid Interrupt Status Bits
in the Rx DS3 Interrupt Enable/Status Register, as depicted below. The Bit Format of the Rx DS3 FEAC
Register is presented below.