English
Language : 

XRT72L50 Datasheet, PDF (411/471 Pages) Exar Corporation – SINGLE CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER
áç
XRT72L50
SINGLE CHANNEL DS3/E3 FRAMER WITH HDLC CONTROLLER
REV. 1.2.1
FIGURE 178. ILLUSTRATION OF TWO EXAMPLES OF HDB3 DECODING
Line Signal
RxPOS
0 00V
B00V
RxNEG
Data
101100000111
10 1 1 0
11 0 0 1 1 0 0 0 0 1
6.3.1.2.3
Line Code Violations
The Receive E3 LIU Interface block will also check the incoming E3 data stream for line code violations. For
example, when the Receive E3 LIU Interface block detects a valid bipolar violation (e.g., in HDB3 line code), it
will substitute four zeros into the binary data stream. However, if the bipolar violation is invalid, then an LCV
(Line Code Violation) is flagged and the PMON LCV Event Count Register (Address = 0x50 and 0x51) will also
be incremented. Additionally, the LCV-One-Second Accumulation Registers (Address = 0x6E and 0x6F) will
be incremented. For example: If the incoming E3 data is HDB3 encoded, the Receive E3 LIU Interface block
will also increment the LCV One-Second Accumulation Register if three (or more) consecutive zeros are
received.
6.3.1.2.4
RxLineClk Clock Edge Selection
The incoming unipolar or bipolar data, applied to the RxPOS and the RxNEG input pins are clocked into the
Receive E3 LIU Interface block via the RxLineClk signal. The Framer IC allows the user to specify which edge
(e.g, rising or falling) of the RxLineClk signal will sample and latch the signal at the RxPOS and RxNEG input
signals into the Framer IC. The user can make this selection by writing the appropriate data to bit 1 of the I/O
Control Register, as depicted below.
I/O Control Register (Address = 0x01)
BIT 7
Disable
TxLOC
R/W
1
BIT 6
LOC
RO
0
BIT 5
Disable
RxLOC
R/W
1
BIT 4
AMI/ZeroSup
R/W
0
BIT 3
Unipolar/
Bipolar
R/W
0
BIT2
BIT 1
TxLine CLK RxLine CLK
Invert
Invert
R/W
R/W
0
0
BIT 0
Reframe
R/W
0
Table 81 depicts the relationship between the value of this bit-field to the sampling clock edge of RxLineClk.
398