Operation of the Receive Payload Data Output Interface block
The Receive Payload Data Output Interface permits the user to read out the payload data of inbound E3
frames, via either of the following modes.
• Serial Mode
• Nibble-Parallel Mode
Each of these modes are described in detail, below.
5.3.5.1 Serial Mode Operation Behavior of the XRT72L50
If the XRT72L50 has been configured to operate in this mode, then the XRT72L50 will behave as follows.
Payload Data Output
The XRT72L50 will output the payload data, of the incoming E3 frames via the RxSer output pin, upon the
rising edge of RxClk.
Delineation of inbound E3 Frames
The XRT72L50 will pulse the RxFrame output pin "High" for one bit-period coincident with it driving the first bit
within a given E3 frame, via the RxSer output pin.
Interfacing the XRT72L50 to the Receive Terminal Equipment
Figure 138 presents a simple illustration as how the user should interface the XRT72L50 to that terminal
equipment which processes Receive Direction payload data.
FIGURE 138. THE TERMINAL EQUIPMENT BEING INTERFACED TO THE RECEIVE PAYLOAD DATA INPUT INTERFACE
BLOCK (SERIAL MODE OPERATION)
Rx_E3_Clock_In
E3_Data_In
Rx_Start_of_Frame
Rx_E3_OH_Ind
34.368MHz
Clock Signal
RxClk
RxSer
RxFrame
RxLineClk
34.368MHz
Clock Source
RxOHInd
Terminal Equipment
Receive Payload Section
E3 Framer
Required Operation of the Terminal Equipment
The XRT72L50 will update the data on the RxSer output pin, upon the rising edge of RxClk. Hence, the
Terminal Equipment should sample the data on the RxSer output pin (or the E3_Data_In pin at the Terminal
Equipment) upon the rising edge of RxClk. As the Terminal Equipment samples RxSer with each rising edge
of RxClk it should also be sampling the following signals.
• RxFrame
• RxOHInd