English
Language : 

HD64F3437TF16 Datasheet, PDF (705/752 Pages) Hitachi Semiconductor – 12 V must not be applied to the S-mask model (single-power-supply specification), as this may permanently damage the device.
ADCSR—A/D Control/Status Register
H'E8
A/D
Bit
Initial value
Read/Write
7
ADF
0
R/(W)*
6
ADIE
0
R/W
5
ADST
0
R/W
4
SCAN
0
R/W
3
CKS
0
R/W
2
CH2
0
R/W
1
CH1
0
R/W
0
CH0
0
R/W
Channel Select
CH2
CH1
0
0
1
1
0
1
CH0
0
1
0
1
0
1
0
1
Single Mode Scan Mode
AN0
AN0
AN1
AN0, AN1
AN2
AN0 to AN2
AN3
AN0 to AN3
AN4
AN4
AN5
AN4, AN5
AN6
AN4 to AN6
AN7
AN4 to AN7
Clock Select
0 Conversion time = 266 states (max)
1 Conversion time = 134 states (max)
Note: When øP = ø
Scan Mode
0 Single mode
1 Scan mode
A/D Start
0 A/D conversion is halted.
1 1. Single mode:
One A/D conversion is performed, then this bit is automatically cleared to 0.
2. Scan mode:
A/C conversion starts and continues cyclically on all selected channels until 0 is
written in this bit.
A/D Interrupt Enable
0 The A/D interrupt request (ADI) is disabled.
1 The A/D interrupt request (ADI) is enabled.
A/D End Flag
0 Cleared from 1 to 0 when CPU reads ADF = 1, then writes 0 in ADF.
1 Set to 1 at the following times:
1. Single mode: at the completion of A/D conversion
2. Scan mode: when all selected channels have been converted.
Note: * Only 0 can be written, to clear the flag.
676