HD64F3437TF16 Datasheet, PDF (564/752 Pages) Hitachi Semiconductor – 12 V must not be applied to the S-mask model (single-power-supply specification), as this may permanently damage the device.
• Notes on Use of Auto-Program Mode
1. In auto-program mode, 128 bytes are programmed simultaneously. This should be carried out
by executing 128 consecutive byte transfers.
2. A 128-byte data transfer is necessary even when programming fewer than 128 bytes. In this
case, H'FF data must be written to the extra addresses.
3. The lower 8 bits of the transfer address must be H'00 or H'80. If a value other than a valid
address is input, processing will switch to a memory write operation but a write error will be
flagged.
4. Memory address transfer is performed in the second cycle (figure 21.19). Do not perform
transfer after the second cycle.
5. Do not perform a command write during a programming operation.
6. Perform one auto-programming operation for a 128-byte block for each address.
Characteristics are not guaranteed for two or more programming operations.
7. Confirm normal end of auto-programming by checking FO6. Alternatively, status read mode
can also be used for this purpose (in FO7 status polling, the pin is the auto-program operation
end identification pin).
8. Status polling FO6 and FO7 pin information is retained until the next command write. As long
as the next command write has not been performed, reading is possible by enabling CE and
OE.