English
Language : 

HD64F3437TF16 Datasheet, PDF (57/752 Pages) Hitachi Semiconductor – 12 V must not be applied to the S-mask model (single-power-supply specification), as this may permanently damage the device.
2.4.2 Calculation of Effective Address
Table 2.2 shows how the H8/300 calculates effective addresses in each addressing mode.
Arithmetic, logic, and shift instructions use register direct addressing (1). The ADD.B, ADDX.B,
SUBX.B, CMP.B, AND.B, OR.B, and XOR.B instructions can also use immediate addressing (6).
The MOV instruction uses all the addressing modes except program-counter relative (7) and
memory indirect (8).
Bit manipulation instructions use register direct (1), register indirect (2), or 8-bit absolute (5)
addressing to identify a byte operand, and 3-bit immediate addressing to identify a bit within the
byte. The BSET, BCLR, BNOT, and BTST instructions can also use register direct addressing (1)
to identify the bit.
28