English
Language : 

SH7020 Datasheet, PDF (65/509 Pages) Renesas Technology Corp – SuperH™ RISC engine
Software Standby Mode: To enter the standby mode, set the standby bit SBY (in the standby
control register SBYCR) to 1 and execute a SLEEP instruction. In standby mode, all CPU, on-chip
peripheral module and oscillator functions are halted. CPU internal register contents and on-chip
RAM data are held.
To return from standby mode, use a reset or an external NMI interrupt. For resets, the CPU returns
to ordinary program execution state through the exception processing state when placed in a reset
state during oscillator stabilization time. For NMI interrupts, the CPU returns to ordinary program
execution state through the exception processing state after the oscillator stabilization time has
elapsed. In this mode, power consumption drops markedly, since the oscillator stops.
Table 2.19 Power-Down State
State
Mode Conditions
On-chip CPU
Peripheral Regi-
Clock CPU Modules sters RAM I/O Ports
Canceling
Sleep
mode
Execute SLEEP Run
instruction with
SBY bit cleared
to 0 in SBYCR
Halt Run
Held Held Held
1. Interrupt
2. DMA address
error
3. Power-on
reset
4. Manual reset
Stand Execute SLEEP Halt
by
instruction with
mode SBY bit set to 1
in SBYCR
Halt Halt and
initialize*
Held
Held Held or
1. NMI
high-Z*
2. Power-on
(selectable)
reset
3. Manual reset
Note: Differs depending on the peripheral module and pin.
44 RENESAS