English
Language : 

SH7020 Datasheet, PDF (317/509 Pages) Renesas Technology Corp – SuperH™ RISC engine
Table 10.22 ITU Operating Modes (Channel 4)
Register Setting
TSNC
TMDR
TFCR
TOCR
TIOR4
TCR4
Reset
Output
Operating
Comp Sync Buf- Level
Clear Clock
Mode Sync MDF FDIR PWM PWM PWM fer Select IOA IOB Select Select
Synch- SYNC4 — — √
√*2 √
√—
√
√
√
√
ronized = 1
preset
PWM
√
— — PWM4 CMD1 CMD1 √ — —
√*1
√
√
=1 =0 =0
Output √
compare A
function
— — PWM4 CMD1 CMD1 √ —
=0 =0 =0
IOA2 = √
0, others
free
√
√
Output √
compare B
function
— —√
CMD1 CMD1 √ — √
=0 =0
IOB2 = √
√
0, others
free
Input
√
capture A
function
— — PWM4 CMD1 CMD1 √ —
=0 =0 =0
IOA2 = √
1, others
free
√
√
Input
√
capture B
function
— — PWM4 CMD1 CMD1 √ — √
=0 =0 =0
IOB2 = √
√
1, others
free
Counter Clear Function
Clear at √
— —√
CMD1 √*3 √ —
√
√
CCLR1 √
compare
= 1,
=0
match/
CMD0
CCLR0
input
=0
=1
capture A
inhibit
ed
Clear at √
— —√
CMD1 √*3 √ —
√
√
CCLR1 √
compare
= 1,
=1
match/
CMD0
CCLR0
input
=0
=0
capture B
inhibit
ed
RENESAS 301