Section 18 RAM
18.1 Usage Notes
18.1.1 Module Standby Mode Setting
RAM can be enabled/disabled by the standby control register. The initial value enables RAM
operation. RAM access is disabled by setting the module standby mode. For details, see section
19, Power-Down Modes.
18.1.2 Address Error
When an address error in write access to the on-chip RAM occurs, the contents of the on-chip
RAM may be corrupted.
18.1.3 Initial Values in RAM
After power has been supplied, initial values in RAM remain undefined until RAM is written.