English
Language : 

SH7125_08 Datasheet, PDF (383/774 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH™ RISC engine Family
Section 9 Multi-Function Timer Pulse Unit 2 (MTU2)
Operation when Error Occurs during PWM Mode 2 Operation, and Operation is Restarted
in Normal Mode: Figure 9.136 shows an explanatory diagram of the case where an error occurs
in PWM mode 2 and operation is restarted in normal mode after re-setting.
1
2
3
4
5
RESET TMDR TIOR PFC TSTR
(PWM2) (1 init (MTU2) (1)
0 out)
6
Match
7
8
9
10 11 12 13
Error PFC TSTR TMDR TIOR PFC TSTR
occurs (PORT) (0) (normal) (1 init (MTU2) (1)
0 out)
MTU2 module output
TIOC*A
Not initialized (cycle register)
TIOC*B
Port output
PEn
High-Z
PEn
High-Z
n = 0 to 15
Figure 9.136 Error Occurrence in PWM Mode 2, Recovery in Normal Mode
1. After a reset, MTU2 output is low and ports are in the high-impedance state.
2. Set PWM mode 2.
3. Initialize the pins with TIOR. (The example shows initial high output, with low output on
compare-match occurrence. In PWM mode 2, the cycle register pins are not initialized. In the
example, TIOC *A is the cycle register.)
4. Set MTU2 output with the PFC.
5. The count operation is started by TSTR.
6. Output goes low on compare-match occurrence.
7. An error occurs.
8. Set port output with the PFC and output the inverse of the active level.
9. The count operation is stopped by TSTR.
10. Set normal mode.
11. Initialize the pins with TIOR.
12. Set MTU2 output with the PFC.
13. Operation is restarted by TSTR.
Rev. 4.00 Jul. 25, 2008 Page 363 of 750
REJ09B0243-0400