English
Language : 

SH7125_08 Datasheet, PDF (395/774 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH™ RISC engine Family
Section 9 Multi-Function Timer Pulse Unit 2 (MTU2)
Operation when Error Occurs during Complementary PWM Mode Operation, and
Operation is Restarted in Reset-Synchronized PWM Mode: Figure 9.148 shows an
explanatory diagram of the case where an error occurs in complementary PWM mode and
operation is restarted in reset-synchronized PWM mode after re-setting.
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17
RESET TOCR TMDR TOER PFC TSTR Match Error PFC TSTR TMDR TOER TOCR TMDR TOER PFC TSTR
(CPWM) (1) (MTU2) (1)
occurs(PORT) (0) (normal) (0)
(RPWM) (1) (MTU2) (1)
MTU2 module output
TIOC3A
TIOC3B
TIOC3D
Port output
PE8
PE9
High-Z
High-Z
PE11
High-Z
Figure 9.148 Error Occurrence in Complementary PWM Mode,
Recovery in Reset-Synchronized PWM Mode
1 to 10 are the same as in figure 9.144.
11. Set normal mode. (MTU2 output goes low.)
12. Disable channel 3 and 4 output with TOER.
13. Select the reset-synchronized PWM mode output level and cyclic output enabling/disabling
with TOCR.
14. Set reset-synchronized PWM.
15. Enable channel 3 and 4 output with TOER.
16. Set MTU2 output with the PFC.
17. Operation is restarted by TSTR.
Rev. 4.00 Jul. 25, 2008 Page 375 of 750
REJ09B0243-0400