English
Language : 

SH7125_08 Datasheet, PDF (398/774 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH™ RISC engine Family
Section 9 Multi-Function Timer Pulse Unit 2 (MTU2)
Operation when Error Occurs during Reset-Synchronized PWM Mode Operation, and
Operation is Restarted in Complementary PWM Mode: Figure 9.151 shows an explanatory
diagram of the case where an error occurs in reset-synchronized PWM mode and operation is
restarted in complementary PWM mode after re-setting.
1
2
3
4
5
6
7
8
9
10 11
12
13
14
15
16
RESET TOCR TMDR TOER PFC TSTR Match Error PFC TSTR TOER TOCR TMDR TOER PFC TSTR
(RPWM) (1) (MTU2) (1)
occurs (PORT) (0) (0)
(CPWM) (1) (MTU2) (1)
MTU2 module output
TIOC3A
TIOC3B
TIOC3D
Port output
PE8
PE9
PE11
High-Z
High-Z
High-Z
Figure 9.151 Error Occurrence in Reset-Synchronized PWM Mode,
Recovery in Complementary PWM Mode
1 to 10 are the same as in figure 9.149.
11. Disable channel 3 and 4 output with TOER.
12. Select the complementary PWM output level and cyclic output enabling/disabling with
TOCR.
13. Set complementary PWM. (The MTU2 cyclic output pin goes low.)
14. Enable channel 3 and 4 output with TOER.
15. Set MTU2 output with the PFC.
16. Operation is restarted by TSTR.
Rev. 4.00 Jul. 25, 2008 Page 378 of 750
REJ09B0243-0400