Section 6 Bus Controller
6.3.4 Bus Control Signal Timing
8-Bit, Three-State-Access Areas: Figure 6.4 shows the timing of bus control signals for an 8-bit,
three-state-access area. The upper address bus (D15 to D8) is used to access these areas. The LWR
pin is always high. Wait states can be inserted.
Bus cycle
T1
T2
T3
φ
Address bus
CS n
External address in area n
AS
RD
Read
access
D15 to D8
D7 to D 0
HWR
Valid
Invalid
Write
access
LWR
D15 to D8
High
Valid
D7 to D 0
Undetermined data
Note: n = 7 to 0
Figure 6.4 Bus Control Signal Timing for 8-Bit, Three-State-Access Area
Rev. 3.00 Mar 21, 2006 page 123 of 814