Section 6 Bus Controller
6.3.3 Data Bus
The H8/3052BF allows either 8-bit access or 16-bit access to be designated for each of areas 0 to
7. An 8-bit-access area uses the upper data bus (D15 to D8). A 16-bit-access area uses both the
upper data bus (D15 to D8) and lower data bus (D7 to D0).
In read access the RD signal applies without distinction to both the upper and lower data bus. In
write access the HWR signal applies to the upper data bus, and the LWR signal applies to the
lower data bus.
Table 6.4 indicates how the two parts of the data bus are used under different access conditions.
Table 6.4 Access Conditions and Data Bus Usage
Area
Access Read
Valid Upper Data Bus
Size
/Write Address Strobe (D15 to D8)
Lower Data Bus
(D7 to D0)
8-bit-access —
area
Read —
Write —
RD
HWR
Valid
Invalid
Undetermined data
16-bit-access Byte Read Even
RD
area
Odd
Valid
Invalid
Invalid
Valid
Write Even
HWR Valid
Undetermined data
Odd
LWR Undetermined data Valid
Word Read —
RD
Valid
Valid
Write —
HWR,
LWR
Valid
Valid
Note: Undetermined data means that unpredictable data is output.
Invalid means that the bus is in the input state and the input is ignored.