English
Language : 

SH7147 Datasheet, PDF (498/1108 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperH™ RISC engine Family
Section 10 Multi-Function Timer Pulse Unit 2 (MTU2) and Multi-Function Timer Pulse Unit 2S (MTU2S)
Operation when Error Occurs during: PWM Mode 2 Operation, and Operation is Restarted
in Phase Counting Mode Figure 10.152 shows an explanatory diagram of the case where an error
occurs in PWM mode 2 and operation is restarted in phase counting mode after re-setting.
MTU2 module output
TIOC*A
1
2
3
4
5
RESET TMDR TIOR PFC TSTR
(PWM2) (1 init (MTU2) (1)
0 out)
6
Match
7
8
9
Error PFC TSTR
occurs (PORT) (0)
10
TMDR
(PCM)
11
12
13
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
Not initialized (cycle register)
TIOC*B
Port output
PEn
Hi-Z
PEn
Hi-Z
n = 0 to 15
Figure 10.152 Error Occurrence in PWM Mode 2, Recovery in Phase Counting Mode
1 to 9 are the same as in figure 10.149.
10. Set phase counting mode.
11. Initialize the pins with TIOR.
12. Set MTU2 output with the PFC.
13. Operation is restarted by TSTR.
Rev. 3.00 Oct. 06, 2008 Page 474 of 1080
REJ09B0230-0300