Section 10 Multi-Function Timer Pulse Unit 2 (MTU2) and Multi-Function Timer Pulse Unit 2S (MTU2S)
Operation when Error Occurs during PWM Mode 1 Operation, and Operation is Restarted
in Reset-Synchronized PWM Mode: Figure 10.148 shows an explanatory diagram of the case
where an error occurs in PWM mode 1 and operation is restarted in reset-synchronized PWM
mode after re-setting.
MTU2 module output
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19
RESET TMDR TOER TIOR PFC TSTR Match Error PFC TSTR TMDR TIOR TIOR TOER TOCR TMDR TOER PFC TSTR
(PWM1) (1) (1 init (MTU2) (1)
occurs (PORT) (0) (normal) (0 init(disabled) (0)
(RPWM) (1) (MTU2) (1)
0 out)
0 out)
TIOC3A
TIOC3B
Not initialized (TIOC3B)
TIOC3D
Not initialized (TIOC3D)
Port output
PE8
Hi-Z
PE9
Hi-Z
PE11
Hi-Z
Figure 10.148 Error Occurrence in PWM Mode 1,
Recovery in Reset-Synchronized PWM Mode
1 to 14 are the same as in figure 10.147.
15. Select the reset-synchronized PWM output level and cyclic output enabling/disabling with
TOCR.
16. Set reset-synchronized PWM.
17. Enable channel 3 and 4 output with TOER.
18. Set MTU2 output with the PFC.
19. Operation is restarted by TSTR.
Rev. 3.00 Oct. 06, 2008 Page 470 of 1080