SH7147 Datasheet, PDF (484/1108 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperH™ RISC engine Family
Section 10 Multi-Function Timer Pulse Unit 2 (MTU2) and Multi-Function Timer Pulse Unit 2S (MTU2S)
Operation when Error Occurs during Normal Mode Operation, and Operation is Restarted
in PWM Mode 1: Figure 10.138 shows an explanatory diagram of the case where an error occurs
in normal mode and operation is restarted in PWM mode 1 after re-setting.
1
2
3
RESET TMDR TOER
(normal) (1)
MTU2 module output
TIOC*A
4
5
6
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
7
Match
8
9
10 11 12
Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM1) (1 init
0 out)
13 14
PFC TSTR
(MTU2) (1)
TIOC*B
Not initialized (TIOC*B)
Port output
PEn
Hi-Z
PEn
Hi-Z
n = 0 to 15
Figure 10.138 Error Occurrence in Normal Mode, Recovery in PWM Mode 1
1 to 10 are the same as in figure 10.137.
11. Set PWM mode 1.
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized. If
initialization is required, initialize in normal mode, then switch to PWM mode 1.)
13. Set MTU2 output with the PFC.
14. Operation is restarted by TSTR.
Rev. 3.00 Oct. 06, 2008 Page 460 of 1080