C8051F93X Datasheet, PDF (320/330 Pages) Silicon Laboratories – Pipelined intstruction architecture executes 70 of instruction in 1 or 2 system clocks
C8051F93x-C8051F92x
SFR Definition 26.3. PCA0PWM: PCA PWM Configuration
Bit
7
6
5
4
3
2
1
0
Name ARSEL ECOV
COVF
CLSEL[1:0]
Type R/W
R/W
R/W
R
R
R
R/W
Reset
0
0
0
0
0
0
0
0
SFR Page = 0x0; SFR Address = 0xDF
Bit Name
Function
7 ARSEL Auto-Reload Register Select.
This bit selects whether to read and write the normal PCA capture/compare registers
(PCA0CPn), or the Auto-Reload registers at the same SFR addresses. This function
is used to define the reload value for 9, 10, and 11-bit PWM modes. In all other
modes, the Auto-Reload registers have no function.
0: Read/Write Capture/Compare Registers at PCA0CPHn and PCA0CPLn.
1: Read/Write Auto-Reload Registers at PCA0CPHn and PCA0CPLn.
6
ECOV Cycle Overflow Interrupt Enable.
This bit sets the masking of the Cycle Overflow Flag (COVF) interrupt.
0: COVF will not generate PCA interrupts.
1: A PCA interrupt will be generated when COVF is set.
5
COVF Cycle Overflow Flag.
This bit indicates an overflow of the 8th, 9th, 10th, or 11th bit of the main PCA counter
(PCA0). The specific bit used for this flag depends on the setting of the Cycle Length
Select bits. The bit can be set by hardware or software, but must be cleared by soft-
ware.
0: No overflow has occurred since the last time this bit was cleared.
1: An overflow has occurred since the last time this bit was cleared.
4:2 Unused Unused.
Read = 000b; Write = don’t care.
1:0 CLSEL[1:0] Cycle Length Select.
When 16-bit PWM mode is not selected, these bits select the length of the PWM
cycle, between 8, 9, 10, or 11 bits. This affects all channels configured for PWM which
are not using 16-bit PWM mode. These bits are ignored for individual channels config-
ured to16-bit PWM mode.
00: 8 bits.
01: 9 bits.
10: 10 bits.
11: 11 bits.