C8051F93x-C8051F92x
24.5. Serial Clock Phase and Polarity
Four combinations of serial clock phase and polarity can be selected using the clock control bits in the SPI
Configuration Register (SPInCFG). The CKPHA bit (SPInCFG.5) selects one of two clock phases (edge
used to latch the data). The CKPOL bit (SPInCFG.4) selects between an active-high or active-low clock.
Both master and slave devices must be configured to use the same clock phase and polarity. SPI0 should
be disabled (by clearing the SPIENn bit, SPInCN.0) when changing the clock phase or polarity. The clock
and data line relationships for master mode are shown in Figure 24.5. For slave mode, the clock and data
relationships are shown in Figure 24.6 and Figure 24.7. Note that CKPHA must be set to 0 on both the
master and slave SPI when communicating between two of the following devices: C8051F04x,
C8051F06x, C8051F12x, C8051F31x, C8051F32x, and C8051F33x.
The SPIn Clock Rate Register (SPInCKR) as shown in SFR Definition 24.3 controls the master mode
serial clock frequency. This register is ignored when operating in slave mode. When the SPI is configured
as a master, the maximum data transfer rate (bits/sec) is one-half the system clock frequency or 12.5 MHz,
whichever is slower. When the SPI is configured as a slave, the maximum data transfer rate (bits/sec) for
full-duplex operation is 1/10 the system clock frequency, provided that the master issues SCK, NSS (in 4-
wire slave mode), and the serial input data synchronously with the slave’s system clock. If the master
issues SCK, NSS, and the serial input data asynchronously, the maximum data transfer rate (bits/sec)
must be less than 1/10 the system clock frequency. In the special case where the master only wants to
transmit data to the slave and does not need to receive data from the slave (i.e. half-duplex operation), the
SPI slave can receive data at a maximum data transfer rate (bits/sec) of 1/4 the system clock frequency.
This is provided that the master issues SCK, NSS, and the serial input data synchronously with the slave’s
system clock.
SCK
(CKPOL=0, CKPHA=0)
SCK
(CKPOL=0, CKPHA=1)
SCK
(CKPOL=1, CKPHA=0)
SCK
(CKPOL=1, CKPHA=1)
MISO/MOSI
NSS (Must Remain High
in Multi-Master Mode)
MSB
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Figure 24.5. Master Mode Data/Clock Timing