English
Language : 

HD64F3028F25 Datasheet, PDF (856/925 Pages) Renesas Technology Corp – Hardware Manual Renesas 16-Bit Single-Chip Microcomputer H8 Family/H8/300H Series
SSR—Serial Status Register
H'FFFB4
SCI0
Bit
Initial value
Read/Write
7
TDRE
1
R/(W)*1
6
RDRF
0
R/(W)*1
5
4
3
ORER
0
R/(W)*1
FER/ERS
0
R/(W)*1
PER
0
R/(W)*1
2
TEND
1
R
1
MPB
0
R
0
MPBT
0
R/W
Multiprocessor bit transfer
0 Multiprocessor bit value in transmit data is 0
1 Multiprocessor bit value in transmit data is 1
Multiprocessor bit
0 Multiprocessor bit value in receive data is 0
1 Multiprocessor bit value in receive data is 1
Transmit end (for serial communication interface)
[Clearing conditions]
0 • Read TDRE when TDRE = 1, then write 0 in TDRE.
• The DMAC writes data in TDR.
[Setting conditions]
• Reset or transition to standby mode
1 • TE is cleared to 0 in SCR.
• TDRE is 1 when last bit of 1-byte serial character is
transmitted.
Transmit end (for smart card interface)
[Clearing conditions]
0 • Read TDRE when TDRE = 1, then write 0 in TDRE.
• The DMAC writes data in TDR.
[Setting conditions]
• Reset or transition to standby mode
1 • TE is cleared to 0 in SCR and FER/ERS is cleared to 0.
• TDRE is 1 and FER/ERS is 0 (normal transmission) 2.5 etu*
(when GM = 0) or 1.0 etu (when GM = 1) after 1-byte serial
character is transmitted.
Note: * etu (Elementary time unit: the time for transfer of one bit)
Parity error
0
[Clearing conditions] • Reset or transition to standby mode
• Read PER when PER = 1, then write 0 in PER.
1
[Setting condition]
Parity error (parity of receive data does not match parity
setting of O/E bit in SMR)
Framing error (for serial communication interface)
0
[Clearing conditions] • Reset or transition to standby mode
• Read FER when FER = 1, then write 0 in FER.
1 [Setting condition] Framing error (stop bit is 0)
Error signal status (for smart card interface)
0
[Clearing conditions] • Reset or transition to standby mode
• Read ERS when ERS = 1, then write 0 in ERS.
1 [Setting condition] A low error signal is received.
Overrun error
0
[Clearing conditions] • Reset or transition to standby mode
• Read ORER when ORER = 1, then write 0 in ORER.
1 [Setting condition] Overrun error (reception of the next serial data ends when RDRF = 1)
Receive data register full
0
[Clearing conditions] • Reset or transition to standby mode
• Read RDRF when RDRF = 1, then write 0 in RDRF.
• The DMAC reads data from RDR.
1 [Setting condition] Serial data is received normally and transferred from RSR to RDR.
Transmit data register empty
0
[Clearing conditions] • Read TDRE when TDRE = 1, then write 0 in TDRE.
• The DMAC writes data in TDR.
[Setting conditions] • Reset or transition to standby mode
1
• TE is 0 in SCR.
• Data is transferred from TDR to TSR, enabling new data to be written in TDR
Note: 1. Only 0 can be written, to clear the flag.
Rev. 2.00, 09/03, page 824 of 890