English
Language : 

HD6413008VF25 Datasheet, PDF (488/688 Pages) Renesas Technology Corp – Old Company Name in Catalogs and Other Documents
15. D/A Converter
15.4 D/A Output Control
In the H8/3008, D/A converter output can be enabled or disabled in software standby mode.
When the DASTE bit is set to 1 in DASTCR, D/A converter output is enabled in software standby
mode. The D/A converter registers retain the values they held prior to the transition to software
standby mode.
When D/A output is enabled in software standby mode, the reference supply current is the same as
during normal operation.
Rev.4.00 Aug. 20, 2007 Page 442 of 638
REJ09B0395-0400