10. Programmable Timing Pattern Controller (TPC)
10.3.5 TPC Output Triggering by Input Capture
TPC output can be triggered by 16-bit timer input capture as well as by compare match. If GRA
functions as an input capture register in the 16-bit timer channel selected in TPCR, TPC output
will be triggered by the input capture signal. Figure 10.8 shows the timing.
φ
TIOC pin
Input capture
signal
NDR
N
DR
M
N
Figure 10.8 TPC Output Triggering by Input Capture (Example)
Rev.4.00 Aug. 20, 2007 Page 306 of 638