13. Smart Card Interface
13.3.4 Register Settings
Table 13.3 shows a bit map of the registers used in the smart card interface. Bits indicated as 0 or
1 must be set to the value shown. The setting of other bits is described in this section.
Table 13.3 Smart Card Interface Register Settings
Bit
Register Address*1 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
SMR
H'FFFB0 GM
0
1
O/E 1
0
CKS1 CKS0
BRR
H'FFFB1 BRR7 BRR6 BRR5 BRR4 BRR3 BRR2 BRR1 BRR0
SCR
H'FFFB2 TIE
RIE
TE
RE
0
0
CKE1*2 CKE0
TDR
H'FFFB3 TDR7 TDR6 TDR5 TDR4 TDR3 TDR2 TDR1 TDR0
SSR
H'FFFB4 TDRE RDRF ORER ERS PER TEND 0
0
RDR
H'FFFB5 RDR7 RDR6 RDR5 RDR4 RDR3 RDR2 RDR1 RDR0
SCMR H'FFFB6 ⎯
⎯
⎯
⎯
SDIR SINV ⎯
SMIF
Legend:
⎯: Unused bit.
Notes: 1. Lower 20 bits of the address in advanced mode.
2. When GM is cleared to 0 in SMR, the CKE1 bit must also be cleared to 0.
Serial Mode Register (SMR) Settings: Clear the GM bit to 0 when using the normal smart card
interface mode, or set to 1 when using GSM mode. Clear the O/E bit to 0 if the smart card is of the
direct convention type, or set to 1 if of the inverse convention type.
Bits CKS1 and CKS0 select the clock source of the built-in baud rate generator. See section
13.3.5, Clock.
Bit Rate Register (BRR) Settings: BRR is used to set the bit rate. See section 13.3.5, Clock, for
the method of calculating the value to be set.
Serial Control Register (SCR) Settings: The TIE, RIE, TE, and RE bits have their normal serial
communication functions. See section 12, Serial Communication Interface, for details. The CKE1
and CKE0 bits specify clock output. To disable clock output, clear these bits to 00; to enable clock
output, set these bits to 01. Clock output is performed when the GM bit is set to 1 in SMR. Clock
output can also be fixed low or high.
Smart Card Mode Register (SCMR) Settings: Clear both the SDIR bit and SINV bit cleared to
0 if the smart card is of the direct convention type, and set both to 1 if of the inverse convention
type. To use the smart card interface, set the SMIF bit to 1.
Rev.4.00 Aug. 20, 2007 Page 394 of 638
REJ09B0395-0400