Section 2 CPU
Condition Code Register (CCR)
This 8-bit register contains internal status information, including the interrupt mask bit (I) and
half-carry (H), negative (N), zero (Z), overflow (V), and carry (C) flags. These bits can be read
and written by software (using the LDC, STC, ANDC, ORC, and XORC instructions). The N, Z,
V, and C flags are used as branching conditions for conditional branching (Bcc) instructions.
Bit 7âInterrupt Mask Bit (I): When this bit is set to 1, interrupts are masked. This bit is set to 1
automatically at the start of exception handling. The interrupt mask bit may be read and written
by software. For further details, see section 3.3, Interrupts.
Bit 6âUser Bit (U): Can be used freely by the user.
Bit 5âHalf-Carry Flag (H): When the ADD.B, ADDX.B, SUB.B, SUBX.B, CMP.B, or NEG.B
instruction is executed, this flag is set to 1 if there is a carry or borrow at bit 3, and is cleared to 0
otherwise.
The H flag is used implicitly by the DAA and DAS instructions.
When the ADD.W, SUB.W, or CMP.W instruction is executed, the H flag is set to 1 if there is a
carry or borrow at bit 11, and is cleared to 0 otherwise.
Bit 4âUser Bit (U): Can be used freely by the user.
Bit 3âNegative Flag (N): Indicates the most significant bit (sign bit) of the result of an
instruction.
Bit 2âZero Flag (Z): Set to 1 to indicate a zero result, and cleared to 0 to indicate a non-zero
result.
Bit 1âOverflow Flag (V): Set to 1 when an arithmetic overflow occurs, and cleared to 0 at other
times.
Bit 0âCarry Flag (C): Set to 1 when a carry occurs, and cleared to 0 otherwise. Used by:
⢠Add instructions, to indicate a carry
⢠Subtract instructions, to indicate a borrow
⢠Shift and rotate instructions, to store the value shifted out of the end bit
The carry flag is also used as a bit accumulator by bit manipulation instructions.
Some instructions leave some or all of the flag bits unchanged.
Refer to the H8/300L Series Software Manual for the action of each instruction on the flag bits.
Rev. 8.00 Mar. 09, 2010 Page 28 of 658
REJ09B0042-0800
|
▷ |