HD64F38024HV Datasheet, PDF (432/684 Pages) Renesas Technology Corp – Hardware Manual Renesas 8-Bit Single-Chip Microcomputer H8 Family/H8/300L Super Low Power Series
Section 12 A/D Converter
12.7.3 Additional Usage Notes
• Data in ADRRH and ADRRL should be read only when the A/D start flag (ADSF) in the A/D
start register (ADSR) is cleared to 0.
• Changing the digital input signal at an adjacent pin during A/D conversion may adversely
affect conversion accuracy.
• When A/D conversion is started after clearing module standby mode, wait for 10 φ clock
cycles before starting.
• In active mode or sleep mode, analog power supply current (AISTOP1) flows into the ladder
resistance even when the A/D converter is not operating. Therefore, if the A/D converter is not
used, it is recommended that AVCC be connected to the system power supply and the
ADCKSTP (A/D converter module standby mode control) bit be cleared to 0 in clock stop
register 1 (CKSTPR1).
Rev. 8.00 Mar. 09, 2010 Page 410 of 658
REJ09B0042-0800