HD64F38024HV Datasheet, PDF (211/684 Pages) Renesas Technology Corp – Hardware Manual Renesas 8-Bit Single-Chip Microcomputer H8 Family/H8/300L Super Low Power Series
Table 6.20 Status Read Mode Return Codes
Pin Name
I/O7
I/O6
I/O5
I/O4
I/O3
I/O2
I/O1
I/O0
Initial Value
0
0
0
0
0
0
0
0
Indications
1: Abnormal end
0: Normal end
1: Command error
0: Otherwise
1: Programming error
0: Otherwise
1: Erasing error
0: Otherwise
⎯
⎯
1: Over counting of writing or erasing
0: Otherwise
1: Effective address error
0: Otherwise
Section 6 ROM
6.10.7 Status Polling
1. The I/O7 status polling flag indicates the operating status in auto-program/auto-erase mode.
2. The I/O6 status polling flag indicates a normal or abnormal end in auto-program/auto-erase
mode.
Table 6.21 Status Polling Output Truth Table
I/O7
I/O6
I/O0 to 5
0
0
0
1
0
0
1
1
0
0
1
0
Status
During internal operation
Abnormal end
Normal end
—
Rev. 8.00 Mar. 09, 2010 Page 189 of 658
REJ09B0042-0800