CHAPTER 20 RESET FUNCTION
The following four operations are available to generate a reset signal.
(1) External reset input via RESET pin
(2) Internal reset by watchdog timer program loop detection
(3) Internal reset by comparison of supply voltage and detection voltage of power-on-clear (POC) circuit
(4) Internal reset by comparison of supply voltage and detection voltage of low-power-supply detector (LVI)
External and internal resets have no functional differences. In both cases, program execution starts at the address
at 0000H and 0001H when the reset signal is generated.
A reset is applied when a low level is input to the RESET pin, the watchdog timer overflows, or by POC and LVI
circuit voltage detection, and each item of hardware is set to the status shown in Tables 20-1 and 20-2. Each pin is
high impedance during reset signal generation or during the oscillation stabilization time just after a reset release.
When a low level is input to the RESET pin, the device is reset. It is released from the reset status when a high
level is input to the RESET pin and program execution is started with the internal high-speed oscillation clock after
reset processing. A reset by the watchdog timer is automatically released, and program execution starts using the
internal high-speed oscillation clock (see Figures 20-2 to 20-4) after reset processing. Reset by POC and LVI circuit
power supply detection is automatically released when VDD ≥ VPOC or VDD ≥ VLVI after the reset, and program
execution starts using the internal high-speed oscillation clock (see CHAPTER 21 POWER-ON-CLEAR CIRCUIT
and CHAPTER 22 LOW-VOLTAGE DETECTOR) after reset processing.
Cautions 1. For an external reset, input a low level for 10 μs or more to the RESET pin.
2. During reset input, the X1 clock, XT1 clock, internal high-speed oscillation clock, and internal
low-speed oscillation clock stop oscillating. External main system clock input becomes
invalid.
3. When the STOP mode is released by a reset, the STOP mode contents are held during reset
input. However, the port pins become high-impedance.
470
User’s Manual U18698EJ1V0UD