CHAPTER 5 CLOCK GENERATOR
Table 5-5. CPU Clock Transition and SFR Register Setting Examples (4/4)
(9) CPU clock changing from subsystem clock (D) to high-speed system clock (C)
(Setting sequence of SFR registers)
Setting Flag of SFR Register
Status Transition
(D) → (C) (X1 clock)
EXCLK
0
(D) → (C) (external main clock)
1
OSCSEL
1
1
MSTOP
OSTC
Register
XSELNote
0
Must be
1
checked
0
Must not be
1
checked
MCM0
1
1
CSS
0
0
Unnecessary if these
registers are already
set
Unnecessary if the
CPU is operating with
the high-speed system
clock
Note The value of this flag can be changed only once after a reset release. This setting is not necessary if it has
already been set.
Caution Set the clock after the supply voltage has reached the operable voltage of the clock to be set (see
CHAPTER 27 ELECTRICAL SPECIFICATIONS (STANDARD PRODUCTS)).
(10) • HALT mode (E) set while CPU is operating with internal high-speed oscillation clock (B)
• HALT mode (F) set while CPU is operating with high-speed system clock (C)
• HALT mode (G) set while CPU is operating with subsystem clock (D)
(B) → (E)
(C) → (F)
(D) → (G)
Status Transition
Executing HALT instruction
Setting
(11) • STOP mode (H) set while CPU is operating with internal high-speed oscillation clock (B)
• STOP mode (I) set while CPU is operating with high-speed system clock (C)
(B) → (H)
(C) → (I)
(Setting sequence)
Status Transition
Setting
Stopping peripheral functions that
cannot operate in STOP mode
Executing STOP instruction
Remarks 1. (A) to (I) in Table 5-5 correspond to (A) to (I) in Figure 5-15.
2. EXCLK, OSCSEL:
Bits 7 and 6 of the clock operation mode select register (OSCCTL)
MSTOP:
Bit 7 of the main OSC control register (MOC)
XSEL, MCM0:
Bits 2 and 0 of the main clock mode register (MCM)
CSS:
Bit 4 of the processor clock control register (PCC)
138