CHAPTER 16 MANCHESTER CODE GENERATOR
16.3 Registers Controlling Manchester Code Generator
The following six types of registers are used to control the Manchester code generator.
• MCG control register 0 (MC0CTL0)
• MCG control register 1 (MC0CTL1)
• MCG control register 2 (MC0CTL2)
• MCG status register (MC0STR)
• Port mode register 3 (PM3)
• Port register 3 (P3)
(1) MCG control register 0 (MC0CTL0)
This register is used to set the operation mode and to enable/disable the operation.
This register can be set by a 1-bit or 8-bit memory manipulation instruction.
Reset signal generation sets this register to 10H.
Figure 16-4. Format of MCG Control Register 0 (MC0CTL0)
Address: FF4CH After reset: 10H R/W
Symbol
<7>
6
5
<4>
3
MC0CTL0 MC0PWR
0
0
MC0DIR
0
2
<1>
<0>
0
MC0OSL MC0OLV
MC0PWR
0
1
Operation stopped
Operation enabled
Operation control
MC0DIR
0
1
MSB
LSB
First bit specification
MC0OSL
0
1
Manchester code
Bit sequential data
Data format
MC0OLV
0
1
Low level
High level
Output level when transmission suspended
Caution Clear (0) the MC0PWR bit before rewriting the MC0DIR, MC0OSL, and MC0OLV bits (it is
possible to rewrite these bits by an 8-bit memory manipulation instruction at the same
time when the MC0PWR bit is set (1)).
User’s Manual U18698EJ1V0UD
413