Command H'43
 Command, H'43, (1 byte) : User-program programming selection
Response H'06
 Response, H'06, (1 byte) : Response to user-program programming selection
When the programming program has been transferred, the boot program will return ACK.
Error
response H'C3
ERROR
 Error response: H'C3 (1 byte): Error response to user MAT programming selection
 ERROR: (1 byte): Error code
H'54: Selection processing error (transfer error occurs and processing is not completed)
(3) 128-byte programming
The boot program will use the programming program transferred by the programming selection to
program the user boot MATs or user MATs.
Command H'50
Address
Data
···
···
SUM
 Command, H'50, (1 byte) : 128-byte programming
 Programming Address (4 bytes) : Start address for programming
Multiple of the size specified in response to the programming unit inquiry
(i.e. H'00, H'01, H'00, H'00 : H'00010000)
 Programming Data (128 bytes) : Data to be programmed
The size is specified in the response to the programming unit inquiry.
 SUM (1 byte) : Checksum
Response H'06
 Response, H'06, (1 byte) : Response to 128-byte programming
On completion of programming, the boot program will return ACK.
Error
response H'D0
ERROR
 Error response, H'D0, (1 byte) : Error response for 128-byte programming
 ERROR : (1 byte) : Error code
H'11 : Checksum Error
H'28 : Address error
The address is not within the specified range.
Rev. 5.0, 09/04, page 662 of 978