Receive Error Flags and Transmitter Operation (Synchronous Mode Only): When a receive
error flag (ORER, PER, or FER) is set to 1 the SCI will not start transmitting, even if the TDRE
flag is cleared to 0. Be sure to clear the receive error flags to 0 when starting to transmit. Note
that clearing the RE bit to 0 does not clear the receive error flags to 0.
Receive Data Sampling Timing in Asynchronous Mode and Receive Margin: In asynchronous
mode the SCI operates on a base clock with 16 times the bit rate frequency. In receiving, the SCI
synchronizes internally with the fall of the start bit, which it samples on the base clock. Receive
data is latched at the rising edge of the eighth base clock pulse. See figure 13.21.
16 clocks
8 clocks
0
7
15 0
7
Internal base clock
15 0
Receive data
(RxD)
Start bit
D0
D1
Synchronization
sampling timing
Data sampling
timing
Figure 13.21 Receive Data Sampling Timing in Asynchronous Mode
The receive margin in asynchronous mode can therefore be expressed as shown in equation (1).
M = (0.5 – 1 ) – (L – 0.5) F – D – 0.5 (1 + F) • 100%
2N
N
. . . . . . . . (1)
M: Receive margin (%)
N: Ratio of clock frequency to bit rate (N = 16)
D: Clock duty cycle (L = 0 to 1.0)
L: Frame length (L = 9 to 12)
F: Absolute deviation of clock frequency
Rev. 5.0, 09/04, page 510 of 978