Electrical Characteristics
Table A-8 shows the configuration of the peripherals for maximum run current
Table A-8. Module Configurations for Maximum Run Supply (VDDR+VDDA) Current VDD35=5.5V
Peripheral
Configuration
S12XCPU
COP & RTI
PLL
DBG
CAN0,CAN1
SPI
SCI0,SCI1
PWM
IIC
LCD
MC
420 cycle loop: 384 DBNE cycles plus subroutine entry to stimulate stacking (RAM access)
enabled. COP running at the rate 224, RTI control register(RTICTL) set to $7F
enabled and configured to supply the part with the maximum specified bus frequency (80 MHz).
the module is enabled and the comparators are configured to trigger in outside range.The range
covers all the code executed by the core,the tracing is disabled..
Configured to loop-back mode using a bit rate of 1Mbit/s
Configured to master mode, continuously transmit data (0x55 or 0xAA) at 1Mbit/s
Configured into loop mode, with the break detection and collision detection features enabled,
continuously transmit data (0x55) at speed of 57600 baud
Configured to toggle its pins at the rate of 40kHz
operate in master mode and continuously transimit data(0x55 or 0xAA) at 100Kbits/s
configured to 976Hz frame frequency, 1/4 Duty, 1/3 Bias with all FP/BP enabled and all
segment on
configured to full H-bridge mode MCPER=0x3FF, 1/2fbus motor controller timer counter
clock, MCDC=0x20
SSD
TIM0,TIM1
ATD
Overhead
disabled
The peripheral shall be configured in output compare mode. Pulse accumulator and modulus
counter enabled.
The peripheral is configured to operate at its maximum specified
frequency and to continuously convert voltages on all input channels in sequence.
VREG supplying 1.8V from a 5V input voltage, PLL on
A.1.10.3 Stop Current Conditions
Unbonded ports must be correctly initialized to prevent current consumption due to floating inputs. Typical
Stop current is measured with VDD35=5V, maximum Stop current is measured with VDD35=5.5V. Pseudo
Stop currents are measured with the oscillator configured for 4MHz LCP mode. Production test parameters
are tested with a 4MHz square wave oscillator.
A.1.10.4 Measurement Results
MC9S12XHY-Family Reference Manual, Rev. 1.01
728
Freescale Semiconductor