Analog-to-Digital Converter (ADC12B12CV1) Block Description
10.3.2.7 ATD Status Register 0 (ATDSTAT0)
This register contains the Sequence Complete Flag, overrun flags for external trigger and FIFO mode, and
the conversion counter.
Module Base + 0x0006
7
R
SCF
W
6
5
4
3
2
1
0
0
CC3
CC2
CC1
CC0
ETORF
FIFOR
Reset
0
0
0
0
0
0
0
0
= Unimplemented or Reserved
Figure 10-9. ATD Status Register 0 (ATDSTAT0)
Read: Anytime
Write: Anytime (No effect on (CC3, CC2, CC1, CC0))
Table 10-16. ATDSTAT0 Field Descriptions
Field
7
SCF
5
ETORF
4
FIFOR
Description
Sequence Complete Flag — This flag is set upon completion of a conversion sequence. If conversion
sequences are continuously performed (SCAN=1), the flag is set after each one is completed. This flag is cleared
when one of the following occurs:
A) Write “1” to SCF
B) Write to ATDCTL5 (a new conversion sequence is started)
C) If AFFC=1 and read of a result register
0 Conversion sequence not completed
1 Conversion sequence has completed
External Trigger Overrun Flag — While in edge trigger mode (ETRIGLE=0), if additional active edges are
detected while a conversion sequence is in process the overrun flag is set. This flag is cleared when one of the
following occurs:
A) Write “1” to ETORF
B) Write to ATDCTL0,1,2,3,4, ATDCMPE or ATDCMPHT (a conversion sequence is aborted)
C) Write to ATDCTL5 (a new conversion sequence is started)
0 No External trigger over run error has occurred
1 External trigger over run error has occurred
Result Register Over Run Flag — This bit indicates that a result register has been written to before its
associated conversion complete flag (CCF) has been cleared. This flag is most useful when using the FIFO mode
because the flag potentially indicates that result registers are out of sync with the input channels. However, it is
also practical for non-FIFO modes, and indicates that a result register has been over written before it has been
read (i.e. the old data has been lost). This flag is cleared when one of the following occurs:
A) Write “1” to FIFOR
B) Write to ATDCTL0,1,2,3,4, ATDCMPE or ATDCMPHT (a conversion sequence is aborted)
C) Write to ATDCTL5 (a new conversion sequence is started)
0 No over run has occurred
1 Overrun condition exists (result register has been written while associated CCFx flag was still set)
MC9S12XHY-Family Reference Manual, Rev. 1.01
332