English
Language : 

HD6417750RF240V Datasheet, PDF (526/606 Pages) Renesas Technology Corp – Renesas 16-Bit Single-Chip Microcomputer H8S Family/H8S/2600 Series
Section 20 Power-Down Modes
20.1 Register Descriptions
Registers related to the power down mode are shown below. For details on the system clock
control register (SCKCR), refer to section 19.1.1, System Clock Control Register (SCKCR). For
details on register addresses and register states during each process, refer to appendix A, On-Chip
I/O Register.
• System clock control register (SCKCR)
• Standby control register (SBYCR)
• Module stop control register A (MSTPCRA)
• Module stop control register B (MSTPCRB)
• Module stop control register C (MSTPCRC)
20.1.1 Standby Control Register (SBYCR)
SBYCR is an 8-bit readable/writable register that performs software standby mode control.
Bit Bit Name
7
SSBY
Initial Value R/W
0
R/W
Description
Software Standby
This bit specifies the transition mode after executing
the SLEEP instruction
0: Shifts to sleep mode when the SLEEP instruction
is executed
1: Shifts to software standby mode when the SLEEP
instruction is executed
This bit does not change when clearing the software
standby mode by using external interrupts and
shifting to normal operation. This bit should be
written with 0 when clearing.
Rev. 7.00 Sep. 11, 2009 Page 490 of 566
REJ09B0211-0700