Section 14 Serial Communication Interface (SCI)
14.6.2 SCI Initialization (Clocked Synchronous Mode)
Before transmitting and receiving data, the TE and RE bits in SCR should be cleared to 0, then the
SCI should be initialized as described in a sample flowchart in figure 14.15. When the operating
mode, or transfer format, is changed for example, the TE and RE bits must be cleared to 0 before
making the change using the following procedure. When the TE bit is cleared to 0, the TDRE flag
is set to 1. Note that clearing the RE bit to 0 does not change the contents of the RDRF, PER,
FER, and ORER flags, or the contents of RDR.
Start initialization
Clear TE and RE bits in SCR to 0
Set CKE1 and CKE0 bits in SCR
(TE, RE bits 0)
[1]
Set data transfer format in
[2]
SMR and SCMR
Set value in BRR
[3]
Wait
No
1-bit interval elapsed?
Yes
[1] Set the clock selection in SCR. Be sure
to clear bits RIE, TIE, TEIE, and MPIE,
TE and RE, to 0.
[2] Set the data transfer format in SMR and
SCMR.
[3] Write a value corresponding to the bit
rate to BRR. Not necessary if an
external clock is used.
[4] Wait at least one bit interval, then set
the TE bit or RE bit in SCR to 1.
Also set the RIE, TIE TEIE, and MPIE
bits.
Setting the TE and RE bits enables the
TxD and RxD pins to be used.
Set TE and RE bits in SCR to 1, and [4]
set RIE, TIE, TEIE, and MPIE bits
<Transfer start>
Note: In simultaneous transmit and receive operations, the TE and RE bits should both be cleared
to 0 or set to 1 simultaneously.
Figure 14.15 Sample SCI Initialization Flowchart
Rev. 7.00 Sep. 11, 2009 Page 356 of 566
REJ09B0211-0700