English
Language : 

HD6417750RF240V Datasheet, PDF (410/606 Pages) Renesas Technology Corp – Renesas 16-Bit Single-Chip Microcomputer H8S Family/H8S/2600 Series
Section 14 Serial Communication Interface (SCI)
When turning on the power or switching between Smart Card interface mode and software standby
mode, the following procedures should be followed in order to maintain the clock duty.
Powering On: To secure clock duty from power-on, the following switching procedure should be
followed.
1. The initial state is port input and high impedance. Use a pull-up resistor or pull-down
resistor to fix the potential.
2. Fix the SCK pin to the specified output level with the CKE1 bit in SCR.
3. Set SMR and SCMR, and switch to smart card mode operation.
4. Set the CKE0 bit in SCR to 1 to start clock output.
When changing from smart card interface mode to software standby mode:
1. Set the data register (DR) and data direction register (DDR) corresponding to the SCK pin
to the value for the fixed output state in software standby mode.
2. Write 0 to the TE bit and RE bit in the serial control register (SCR) to halt transmit/receive
operation. At the same time, set the CKE1 bit to the value for the fixed output state in
software standby mode.
3. Write 0 to the CKE0 bit in SCR to halt the clock.
4. Wait for one serial clock period.
During this interval, clock output is fixed at the specified level, with the duty preserved.
5. Make the transition to the software standby state.
When returning to smart card interface mode from software standby mode:
1. Exit the software standby state.
2. Write 1 to the CKE0 bit in SCR and output the clock. Signal generation is started with the
normal duty.
Normal operation
Software
standby
Normal operation
[1] [2] [3]
[4] [5]
[1] [2]
Figure 14.32 Clock Halt and Restart Procedure
Rev. 7.00 Sep. 11, 2009 Page 374 of 566
REJ09B0211-0700