English
Language : 

HD6417750RF240V Datasheet, PDF (399/606 Pages) Renesas Technology Corp – Renesas 16-Bit Single-Chip Microcomputer H8S Family/H8S/2600 Series
Section 14 Serial Communication Interface (SCI)
Initialization
[1]
Start transmission/reception
Read TDRE flag in SSR
[2]
No
TDRE = 1
Yes
Write transmit data to TDR and
clear TDRE flag in SSR to 0
Read ORER flag in SSR
ORER = 1
No
Yes
[3]
Error processing
Read RDRF flag in SSR
[4]
No
RDRF = 1
[1] SCI initialization:
The TxD pin is designated as the
transmit data output pin, and the RxD
pin is designated as the receive data
input pin, enabling simultaneous
transmit and receive operations.
[2] SCI status check and transmit data
write:
Read SSR and check that the TDRE
flag is set to 1, then write transmit
data to TDR and clear the TDRE flag
to 0.
Transition of the TDRE flag from 0 to
1 can also be identified by a TXI
interrupt.
[3] Receive error processing:
If a receive error occurs, read the
ORER flag in SSR, and after
performing the appropriate error
processing, clear the ORER flag to 0.
Transmission/reception cannot be
resumed if the ORER flag is set to 1.
[4] SCI status check and receive data
read:
Read SSR and check that the RDRF
flag is set to 1, then read the receive
data in RDR and clear the RDRF flag
to 0. Transition of the RDRF flag from
0 to 1 can also be identified by an RXI
interrupt.
Yes
[5]
Read receive data in RDR, and
clear RDRF flag in SSR to 0
No
All data received?
[5]
Yes
Clear TE and RE bits in SCR to 0
<End>
Note: When switching from transmit or receive operation to simultaneous
transmit and receive operations, first clear the TE bit and RE bit to 0,
then set both these bits to 1 simultaneously.
Serial transmission/reception
continuation procedure:
To continue serial transmission/
reception, before the MSB (bit 7) of
the current frame is received, finish
reading the RDRF flag, reading RDR,
and clearing the RDRF flag to 0.
Also, before the MSB (bit 7) of the
current frame is transmitted, read 1
from the TDRE flag to confirm that
writing is possible. Then write data to
TDR and clear the TDRE flag to 0.
Checking and clearing of the TDRE
flag is automatic when the DTC is
activated by a transmit data empty
interrupt (TXI) request and data is
written to TDR. Also, the RDRF flag is
cleared automatically when the DTC
is activated by a receive data full
interrupt (RXI) request and the RDR
value is read.
Figure 14.20 Sample Flowchart of Simultaneous Serial Transmit and Receive Operations
Rev. 7.00 Sep. 11, 2009 Page 363 of 566
REJ09B0211-0700