English
Language : 

HD6417750RF240V Datasheet, PDF (388/606 Pages) Renesas Technology Corp – Renesas 16-Bit Single-Chip Microcomputer H8S Family/H8S/2600 Series
Section 14 Serial Communication Interface (SCI)
14.5.2 Multiprocessor Serial Data Reception
Figure 14.13 shows a sample flowchart for multiprocessor serial data reception. If the MPIE bit in
SCR is set to 1, data is skipped until data with a 1 multiprocessor bit is sent. On receiving data
with a 1 multiprocessor bit, the receive data is transferred to RDR. An RXI interrupt request is
generated at this time. All other SCI operations are the same as in asynchronous mode. Figure
14.12 shows an example of SCI operation for multiprocessor format reception.
Start
1 bit
Data (ID1)
Stop Start
MPB bit bit
Data (Data1)
Stop
MPB bit
1
0 D0 D1
D7 1
1 0 D0 D1
D7 0
1 Idle state
(mark state)
MPIE
RDRF
RDR
value
ID1
MPIE = 0
RXI interrupt
request
(multiprocessor
interrupt)
generated
RDR data read
and RDRF flag
cleared to 0 in
RXI interrupt
service routine
If not this station’s ID,
MPIE bit is set to 1
again
RXI interrupt request is
not generated, and RDR
retains its state
(a) Data does not match station’s ID
Start
1 bit
Data (ID2)
Stop Start
MPB bit bit
Data (Data2)
Stop
MPB bit
1
0 D0 D1
D7 1 1 0 D0 D1
D7 0
1 Idle state
(mark state)
MPIE
RDRF
RDR
value
ID1
MPIE = 0
ID2
Data2
RXI interrupt
request
(multiprocessor
interrupt)
generated
RDR data read and
RDRF flag cleared
to 0 in RXI interrupt
service routine
Matches this station’s ID,
so reception continues, and
data is received in RXI
interrupt service routine
MPIE bit set to 1
again
(b) Data matches station’s ID
Figure 14.12 Example of SCI Operation in Reception
(Example with 8-Bit Data, Multiprocessor Bit, One Stop Bit)
Rev. 7.00 Sep. 11, 2009 Page 352 of 566
REJ09B0211-0700