• Bit 15—Connection Flag 8P (CN8P): Enables or disables connection between DST8P and the
channel 2 down-count start trigger.
Bit 15: CN8P
0
1
Description
Connection between DST8P and channel 2 down-count start trigger H is
disabled
(Initial value)
Connection between DST8P and channel 2 down-count start trigger H is
enabled
• Bit 14—Connection Flag 8O (CN8O): Enables or disables connection between DST8O and the
channel 2 down-count start trigger.
Bit 14: CN8O
0
1
Description
Connection between DST8O and channel 2 down-count start trigger G is
disabled
(Initial value)
Connection between DST8O and channel 2 down-count start trigger G is
enabled
• Bit 13—Connection Flag 8N (CN8N): Enables or disables connection between DST8N and the
channel 2 down-count start trigger.
Bit 13: CN8N
0
1
Description
Connection between DST8N and channel 2 down-count start trigger F is
disabled
(Initial value)
Connection between DST8N and channel 2 down-count start trigger F is
enabled
• Bit 12—Connection Flag 8M (CN8M): Enables or disables connection between DST8M and
the channel 2 down-count start trigger.
Bit 12: CN8M
0
1
Description
Connection between DST8M and channel 2 down-count start trigger E is
disabled
(Initial value)
Connection between DST8M and channel 2 down-count start trigger E is
enabled