GMS30C7201 Datasheet, PDF (270/352 Pages) Hynix Semiconductor – 60MHz operation frequency Low power consumption
Slow AMBA Peripherals
13.7 Timers
13.7.1 In/Out signals
The timer has the following features:
• 32-bit up ripple counter
• Auto repeat mode
• Count enable/disable
• Interrupt enable/disable
• 3-timer channel
Signal
PCLK
PD[31:0]
PA[6:2]
PSEL
PSTB
PWRITE
INTTIMER
Type
In
In/Out
In
In
In
In
Out
BnRES
In
Description
Clock Source
Data Bus
Address Bus
Chip Select
Strobe
nRead/Write
“1” when counter register value is equal to the
base register value.
Reset Signal
Table 13-32: Timers in/out signals
13-42
GMS30C7201 Data Sheet