XRT74L73 Datasheet, PDF (363/488 Pages) Exar Corporation – 3 CHANNEL, ATM UNI/PPP DS3/E3 FRAMING CONTROLLER
PRELIMINARY
XRT74L73
3 CHANNEL, ATM UNI/PPP DS3/E3 FRAMING CONTROLLER
REV. P1.0.1
TABLE 81: LISTING AND DESCRIPTION OF THE PIN ASSOCIATED WITH THE RECEIVE OVERHEAD DATA OUTPUT
INTERFACE BLOCK (METHOD 2)
SIGNAL NAME
RxOH
RxOHEnable
RxOHFrame
RxOutClk
TYPE
DESCRIPTION
Output
Receive Overhead Data Output pin:
The XRT74L73 will output the overhead bits, within the incoming E3 frames, via this pin.
The Receive Overhead Output Interface will pulse the RxOHEnable output pin (for one RxOut-
Clk period) at approximately the middle of the RxOH bit period. The user is advised to design
the Terminal Equipment to latch the contents of the RxOH output pin, whenever the RxOHEn-
able output pin is sampled "High” on the falling edge of RxOutClk.
Output Receive Overhead Data Output Enable - Output pin:
The XRT74L73 will assert this output signal for one RxOutClk period when it is safe for the Ter-
minal Equipment to sample the data on the RxOH output pin.
Output Receive Overhead Data Output Interface - Start of Frame Indicator:
The XRT74L73 will drive this output pin "High” (for one period of the RxOH signal), whenever
the first overhead bit, within a given E3 frame is being driven onto the RxOH output pin.
Output
Receive Section Output Clock Signal:
This clock signal is derived from the RxLineClk signal (from the LIU) for loop-timing applica-
tions, and the TxInClk signal (from a local oscillator) for local-timing applications. For E3 appli-
cations, this clock signal will operate at 34.368MHz.
The user is advised to design the Terminal Equipment to latch the contents of the RxOH pin,
anytime the RxOHEnable output signal is sampled "High” on the falling edge of this clock sig-
nal.
Interfacing the Receive Overhead Data Output In-
terface block to the Terminal Equipment (Method
2)
Figure 154 illustrates how one should interface the
Receive Overhead Data Output Interface block to the
Terminal Equipment, when using Method 2 to sample
and process the overhead bits from the inbound E3
data stream.
FIGURE 154. HOW TO INTERFACE THE TERMINAL EQUIPMENT TO THE RECEIVE OVERHEAD DATA OUTPUT INTER-
FACE BLOCK FOR METHOD 2
E3_OH_In
E3_OH_Enable_In
E3_Clk_In
Rx_Start_of_Frame
RxOH
RxOHEnable
RxOutClk
RxOHFrame
Terminal Equipment
XRT74L73 E3 Framer
Method 2 Operation of the Terminal Equipment
If the Terminal Equipment intends to sample any
overhead data from the inbound E3 data stream (via
364