Figure 44 presents a timing diagram, that depicts the
behavior of the ATM Layer processorâs and the UNIâs
signals during polling.
FIGURE 44. TIMING DIAGRAM ILLUSTRATING THE BEHAVIOR OF VARIOUS SIGNALS FROM THE ATM LAYER PROCESSOR
AND THE UNI, DURING POLLING.
1
2
3
4
5
6
7
8
9
10
11
12
RxUClk
RxUAddr[4:0] 01h 1Fh
RxUClav
01h
RxUEn
RxUData [15:0] W27 W0
RxUSoC
03h 1Fh
03h
01h 03h 1Fh
01h 03h
03h 01h
03h
1Fh
01h
01h 03h
01h
W1
W2 W3
W4
W5
W6 W7
W8
W9 W10
Note: regarding Figure 44
1. The Receive UTOPIA Data bus is configured to be
16 bits wide. Hence, the data, which the ATM Layer
processor places on the Receive UTOPIA Data
bus, is expressed in terms of 16 bit words: (e.g.,
W0âW26).
2. The Receive UTOPIA Interface block is configured to
handle 54 bytes/cell. Hence, Figure 44 illustrates the
ATM Layer processor reading 27 words (W0 through
W26) for each ATM cell.
3. The ATM Layer processor is currently reading ATM cell
data from the Receive UTOPIA Interface block, within
UNI #1 (RxUAddr[4:0] = 01h) during this âpolling pro-
cessâ.
4. The RxFIFO, within UNI#2âs Receive UTOPIA Interface
block (RxUAddr[4:0] = 03h) is either depleted or does
not contain enough data to constitute a complete ATM
cell. Hence, the RxUClav line will be driven âlowâ
whenever this particular Receive UTOPIA Interface
block is âpolledâ.
5. The Receive UTOPIA Address of 1Fh is not associated
with any UNI device, within this âMulti-PHYâ system.
Hence, the RxUClav line is tri-stated whenever this
address is âpolledâ.
Note: Although Figure 44 depicts connections between the
Transmit UTOPIA Interface block pins and the ATM Layer
processor; the Transmit UTOPIA Interface operation, in the
Multi-PHY mode, will not be discussed in this section. Please
see Section 6.1.2.3.2.1 for a discussion on the Transmit
UTOPIA Interface block during Multi-PHY operation.
3.4.2.2.3.1.2Reading ATM Cell Data from
a Different UNI
After the ATM Layer processor has âpolledâ each of
the UNI devices within its system, it must now select
a UNI, and begin reading ATM cell data from that
device. The ATM Layer processor makes its selection
and begins the reading process by:
1. Applying the UTOPIA Address of the âtargetâ UNI on
the âUTOPIA Address Busâ.
2. Negate the RxUEn signal. This step causes the
âaddressedâ UNI to recognize that it has been selected
to transmit the next set of ATM cell data to the ATM
Layer processor.
3. Assert the RxUEn signal.
4. Check and insure that the RxUSoC output pin (of the
selected UNI) pulses âhighâ when the first byte or
word of ATM cell data has been placed on the Receive
UTOPIA Data Bus.
5. Begin reading the ATM Cell data in a byte-wide (or
word-wide) manner from the Receive UTOPIA Data
bus.
Figure 45 presents a flow-chart that depicts the âUNI
Device Selection and Readâ process in Multi-PHY opera-
tion.
173
|
▷ |