Section 10 16-Bit Integrated Timer Unit (ITU)
Timing of Setting of IMFA and IMFB by Input Capture
IMFA and IMFB are set to 1 by an input capture signal. The TCNT contents are simultaneously
transferred to the corresponding general register. Figure 10.58 shows the timing.
φ
Input capture
signal
IMF
TCNT
N
GR
N
IMI
Figure 10.58 Timing of Setting of IMFA and IMFB by Input Capture