HD64F3048F16 Datasheet, PDF (361/903 Pages) Renesas Technology Corp – Old Company Name in Catalogs and Other Documents | |||
|
◁ |
Section 10 16-Bit Integrated Timer Unit (ITU)
Bit 3âTimer Sync 3 (SYNC3): Selects whether channel 3 operates independently or
synchronously.
Bit 3: SYNC3
0
1
Description
Channel 3âs timer counter (TCNT3) operates independently
TCNT3 is preset and cleared independently of other channels
Channel 3 operates synchronously
TCNT3 can be synchronously preset and cleared
(Initial value)
Bit 2âTimer Sync 2 (SYNC2): Selects whether channel 2 operates independently or
synchronously.
Bit 2: SYNC2
0
1
Description
Channel 2âs timer counter (TCNT2) operates independently
TCNT2 is preset and cleared independently of other channels
Channel 2 operates synchronously
TCNT2 can be synchronously preset and cleared
(Initial value)
Bit 1âTimer Sync 1 (SYNC1): Selects whether channel 1 operates independently or
synchronously.
Bit 1: SYNC1
0
1
Description
Channel 1âs timer counter (TCNT1) operates independently
TCNT1 is preset and cleared independently of other channels
Channel 1 operates synchronously
TCNT1 can be synchronously preset and cleared
(Initial value)
Bit 0âTimer Sync 0 (SYNC0): Selects whether channel 0 operates independently or
synchronously.
Bit 0: Bit 0
0
1
Description
Channel 0âs timer counter (TCNT0) operates independently
TCNT0 is preset and cleared independently of other channels
Channel 0 operates synchronously
TCNT0 can be synchronously preset and cleared
(Initial value)
Rev. 3.00 Sep 27, 2006 page 333 of 872