The General Purpose Timer Units
Field
T5CC
CT3
T5RC
T5UD
T5R
T5M
T5I
Bits Typ Description
11
rw
Timer T5 Capture Correction
0 T5 is just captured without any correction
1 T5 is decremented by 1 before being captured
10
rw
Timer T3 Capture Trigger Enable
0 Capture trigger from input line CAPIN
1 Capture trigger from T3 input lines T3IN and/or
T3EUD
9
rw
Timer T5 Remote Control
0 Timer T5 is controlled by its own run bit T5R
1 Timer T5 is controlled by the run bit T6R of
core timer 6, not by bit T5R
7
rw
Timer T5 Up/Down Control
0 Timer T5 counts up
1 Timer T5 counts down
6
rw
Timer T5 Run Bit
0 Timer T5 stops
1 Timer T5 runs
Note: This bit only controls timer T5 if bit T5RC = 0.
[5:3] rw
Timer T5 Mode Control (Basic Operating Mode)
000 Timer Mode
001 Counter Mode
010 Gated Timer Mode with gate active low
011 Gated Timer Mode with gate active high
1XX Reserved. Do not use this combination
[2:0] rw
Timer T5 Input Parameter Selection
Depends on the operating mode, see respective
sections for encoding:
Table 14-15 for Timer Mode and Gated Timer Mode
Table 14-11 for Counter Mode
Timer T5 Run Control
The auxiliary timer T5 can be started or stopped by software in two different ways:
• Through the associated timer run bit (T5R). In this case it is required that the
respective control bit T5RC = 0.
• Through the core timer’s run bit (T6R). In this case the respective remote control bit
must be set (T5RC = 1).
The selected run bit is relevant in all operating modes of T5. Setting the bit will start the
timer, clearing the bit stops the timer.