XC161 Datasheet, PDF (257/419 Pages) Infineon Technologies AG – 16-Bit Single-Chip Microcontroller with C166SV2 Core Volume 2 (of 2): Peripheral Units
XC161 Derivatives
Peripheral Units (Vol. 2 of 2)
TwinCAN Module
21.1.4.2 Handling of Remote and Data Frames
Message objects can be set up for transmit or receive operation according to the
selected value for control bit DIR. The impact of the message object type on the
associated CAN node controller concerning the generation or reception of remote and
data frames is illustrated in Table 21-1.
Table 21-1 Handling of Remote and Data Frames
A transmission
request (TXRQ =
‘10’) for this
message object
generates …
If a data frame with If a remote frame
matching identifier with matching
is received …
identifier is
received …
Receive Object
(receives data
frames, transmits
remote frames,
control bit DIR = ‘0’)
… a remote frame.
The requested data
frame is stored in
this message object
on reception.
… the data frame is
stored in this
message object.
… the remote frame
is NOT taken into
account.
Transmit Object
(transmits data
frames, receives
remote frames,
control bit DIR = ‘1’)
… a data frame
… the data frame is
based upon the
NOT stored.
information stored in
this message
object.
… the remote frame
is stored in this
message object and
RMTPND and
TXRQ are set to
‘10’.
A data frame, based
upon the
information stored in
this message
object, is
automatically
generated if
CPUUPD is set to
‘01’.
User’s Manual
TwinCAN_X1, V2.1
21-17
V2.2, 2004-01