English
Language : 

XC161 Datasheet, PDF (312/419 Pages) Infineon Technologies AG – 16-Bit Single-Chip Microcontroller with C166SV2 Core Volume 2 (of 2): Peripheral Units
Field
RMM
NODE
XTD
DIR
DLC1)
XC161 Derivatives
Peripheral Units (Vol. 2 of 2)
TwinCAN Module
Bits Type Description
0
rw
Low
Transmit Message Object Remote Monitoring
Mode
0 Remote Monitoring mode is disabled.
1 Remote Monitoring mode is enabled for this
transmit message object. The identifier and DLC
code of a remote frame with matching identifier
are copied to this transmit message object in
order to monitor incoming remote frames.
Bit RMM is only available for transmit objects and has
no impact for receive objects.
1
rwh Message Object CAN Node Select
Low
0 The message object is assigned to CAN node A.
1 The message object is assigned to CAN node B.
2
rw
Low
Message Object Extended Identifier
0 This message object uses a standard 11-bit
identifier.
1 This message object uses an extended 29-bit
identifier.
3
rwh Message Object Direction Control
Low
0 The message object is defined as receive
object. If TXRQ = ‘10’, a remote frame with the
identifier of this message object is transmitted.
On reception of a data frame with matching
identifier, the message data is stored in the
corresponding MSGDRn0/MSGDRn4 registers.
1 The message object is declared as transmit
object. If TXRQ = ‘10’, the respective data frame
is transmitted. On reception of a remote frame
with matching identifier, RMTPND and TXRQ
are set to ‘10’.
[7:4] rwh Message Object Data Length Code
Low
0000B - 1XXXB
DLC contains the number of data bytes associated to
the message object.
Bitfield DLC may be modified by hardware in Remote
Monitoring Mode and in Gateway Mode.
User’s Manual
TwinCAN_X1, V2.1
21-72
V2.2, 2004-01