English
Language : 

MC3S12RG128 Datasheet, PDF (379/546 Pages) Freescale Semiconductor, Inc – Microcontrollers
Chapter 12 Freescale’s Scalable Controller Area Network (MSCANV2)
Read: Anytime when TXEx flag is set (see Section 12.3.2.7, “MSCAN Transmitter Flag Register
(CANTFLG)”) and the corresponding transmit buffer is selected in CANTBSEL (see Section 12.3.2.11,
“MSCAN Transmit Buffer Selection Register (CANTBSEL)”).
Write: Unimplemented
12.4 Functional Description
12.4.1 General
This section provides a complete functional description of the MSCAN. It describes each of the features
and modes listed in the introduction.
MC3S12RG128 Data Sheet, Rev. 1.05
Freescale Semiconductor
379