English
Language : 

MC68HC908AT32 Datasheet, PDF (209/378 Pages) Freescale Semiconductor, Inc – Microcontrollers
Functional Description
PWM function, and TIMB channel 1 status and control register (TBSC1) is unused. While the MS0B bit is
set, the channel 1 pin, PTF5/TBCH1, is available as a general-purpose I/O pin.
NOTE
In buffered PWM signal generation, do not write new pulse width values to
the currently active channel registers. Writing to the active channel
registers is the same as generating unbuffered PWM signals.
19.3.4.3 PWM Initialization
To ensure correct operation when generating unbuffered or buffered PWM signals, use this initialization
procedure:
1. In the TIMB status and control register (TBSC):
a. Stop the TIMB counter by setting the TIMB stop bit, TSTOP.
b. Reset the TIMB counter by setting the TIMB reset bit, TRST.
2. In the TIMB counter modulo registers (TBMODH–TBMODL), write the value for the required PWM
period.
3. In the TIMB channel x registers (TBCHxH–TBCHxL), write the value for the required pulse width.
4. In TIMB channel x status and control register (TBSCx):
a. Write 0:1 (for unbuffered output compare or PWM signals) or 1:0 (for buffered output compare
or PWM signals) to the mode select bits, MSxB–MSxA. (See Table 19-2.)
b. Write 1 to the toggle-on-overflow bit, TOVx.
c. Write 1:0 (to clear output on compare) or 1:1 (to set output on compare) to the edge/level
select bits, ELSxB–ELSxA. The output action on compare must force the output to the
complement of the pulse width level. (See Table 19-2.)
NOTE
In PWM signal generation, do not program the PWM channel to toggle on
output compare. Toggling on output compare prevents reliable 0 percent
duty cycle generation and removes the ability of the channel to self-correct
in the event of software error or noise. Toggling on output compare can also
cause incorrect PWM signal generation when changing the PWM pulse
width to a new, much larger value.
5. In the TIMB status control register (TBSC), clear the TIMB stop bit, TSTOP.
Setting MS0B links channels 0 and 1 and configures them for buffered PWM operation. The TIMB channel
0 registers (TBCH0H–TBCH0L) initially control the buffered PWM output. TIMB status control register 0
(TBSC0) controls and monitors the PWM signal from the linked channels. MS0B takes priority over MS0A.
Clearing the toggle-on-overflow bit, TOVx, inhibits output toggles on TIMB overflows. Subsequent output
compares try to force the output to a state it is already in and have no effect. The result is a 0% duty cycle
output.
Setting the channel x maximum duty cycle bit (CHxMAX) and clearing the TOVx bit generates a 100
percent duty cycle output. See 19.8.4 TIMB Channel Status and Control Registers.
MC68HC908AT32 Data Sheet, Rev. 3.1