Chapter 2: Cyclone IV Reset Control and Power Down
Dynamic Reconfiguration Reset Sequences
2. After the PLL is reset, wait for the pll_locked signal to go high (marker 4)
indicating that the PLL is locked to the input reference clock. After the assertion of
the pll_locked signal, deassert the tx_digitalreset signal (marker 5).
3. Wait at least five parallel clock cycles after the pll_locked signal is asserted to
deassert the rx_analogreset signal (marker 6).
4. When the rx_freqlocked signal goes high (marker 7), from that point onwards,
wait for at least tLTD_Auto time, then deassert the rx_digitalreset signal
(marker 8). At this point, the receiver is ready for data traffic.
Reset Sequence in Channel Reconfiguration Mode
Use the example reset sequence shown in Figure 2–12 when you are using the
dynamic reconfiguration controller to change the PCS settings of the transceiver
channel. In this example, the dynamic reconfiguration is used to dynamically
reconfigure the transceiver channel configured in Basic ×1 mode with receiver CDR in
automatic lock mode.
Figure 2–12. Reset Sequence When Using the Dynamic Reconfiguration Controller to Change the
PCS Settings of the Transceiver Channel
Reset and Control Signals
1
tx_digitalreset
1
rx_analogreset
1
rx_digitalreset
5
6
8
reconfig_mode_sel[2..0]
write_all
New value
1
Output Status Signals
busy (2)
channel_reconfig_done
rx_freqlocked
Five parallel clock cycles
2
3
4
7
tLTD_Auto (1)
Notes to Figure 2–12:
(1) For tLTD_Auto duration, refer to the Cyclone IV Device Datasheet chapter.
(2) The busy signal is asserted and deasserted only during initial power up when offset cancellation occurs. In
subsequent reset sequences, the busy signal is asserted and deasserted only if there is a read or write operation to
the ALTGX_RECONFIG megafunction.